LC1D65AP7C TeSys Deca contactor, 3-pole (3NO),AC-3/AC-3e,<=440V,65A,230VAC,Everlink terminal
LC1D65AP7C of TeSys series is a 3-level AC contactor, conforming to IEC60947-1/GB14048.4 standard requirements, rated working current 65A,AC-3, overvoltage class III, pollution level 3, front side meets IP20 protection level. Power 18.5KW,380~400V, AC control circuit voltage 230V@50/60Hz coil, with 1 normally open and 1 normally closed auxiliary contact, EverLink terminal, the product can be clamp-mounted on 35mm guide rail or screw fixed to the mounting plate, in line with CCC and CE certification.
Specification
| Type | LC1D65AP7C |
|---|---|
| Order Number | LC1D65AP7C |
| Brand | Schneider |
| Place of Origin | France |
| Product Series | TeSys Deca |
| Product type | contactor |
| Product short name | LC1D |
| Contactor application field |
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non inductive or micro inductive load, resistance furnace
|
| use classes |
AC-4
AC-1
AC-3
AC-3e
|
| number of poles | 3 |
| Rated operating voltage [Ue] |
Power supply circuit: <= 690 V AC 25... 400 Hz
Power supply circuit: <= 225 V DC
|
| Rated operating current [Ie] | 80 A (when operating temperature <=60 °C) When operating voltage <=<= 440 V AC AC-1 for the power supply circuit
65 A (when operating temperature <=60 °C) When operating voltage <=<= 440 V AC AC-3 for power supply circuit
65 A (when operating temperature <=60 °C) When operating voltage <=<= 440 V AC AC-3E for power supply circuit
|
| Control loop voltage [Uc] | 230 V AC 50/60 Hz |
| Motor power (kW) | 37 kW When operating voltage <=500 V AC 50/60 Hz (AC-3)
18.5kW When operating voltage <=220/240 V AC 50/60 Hz (AC-3)
30 kW When operating voltage <=380/400 V AC 50/60 Hz (AC-3)
37 kW When operating voltage <=660/690 V AC 50/60 Hz (AC-3)
37 kW when operating voltage <=415/440 V AC 50/60 Hz (AC-3)
37 kW When operating voltage <=500 V AC 50/60 Hz (AC-3E)
18.5kW When operating voltage <=220/240 V AC 50/60 Hz (AC-3E)
30 kW When operating voltage <=380/400 V AC 50/60 Hz (AC-3E)
37 kW When operating voltage <=660/690 V AC 50/60 Hz (AC-3E)
37 kW when operating voltage <=415/440 V AC 50/60 Hz (AC-3E)
|
| type | LC1D |
| Loop contact type | 3 NO |
| protective cap | Yes |
| Conventional heating current [Ith] | 10 A (when operating temperature <=60 °C) for signal loop
80 A (when operating temperature <=60 °C) for the power supply circuit
|
| Rated short-time withstand current [Icw] | 520 A Sustainable for 10 s for power circuits when operating temperature <=40 °C
900 A sustainable for 1 s for power circuits when operating temperature <=40 °C
110 A can last for 10 minutes for power circuits when operating temperature <=40 °C
260 A when operating temperature <=40 °C sustainable for 1 minute for the power circuit
100 A sustainable 1 s for the signal loop
120 A sustainable 500 ms for the signal loop
140 A sustainable 100 ms for the signal loop
|
| average impedance | 1.5 mΩ-Ith 80 A 50 Hz For power supply loop |
| Rated insulation voltage [Ui] | Power supply circuit: 690 V in accordance with IEC 60947-4-1
Signal loop: 690 V in accordance with IEC 60947-1
|
| Overvoltage class | III |
| Rated impulse withstand voltage [Uimp] | 6 kV in accordance with IEC 60947 |
| mechanical life | 6 Mcycles |
| Control loop characteristic | AC when 50/60 Hz |
| Surge suppression module | No built-in surge suppression module |
| dissipation of heat | 4…5 W at 50/60 Hz |
| actuation time | 12... 26 ms closure
4... 19 ms is disconnected
|
| Maximum operating frequency | 3600 times/hour at 60 °C |
| Auxiliary contacts available on each contactor | 1 NO + 1 NC |
| Signal loop frequency | 25...400 Hz |
| Minimum switching current [Imin] | 5 mA for signal loop |
| Minimum switching voltage | 17 V for signal loop |
| insulation resistance | > 10 MΩ for signal loop |
| No overlapping time | 1.5ms power loss between NC and NO contact
1.5ms power between NC and NO contact
|
| way to install |
Rail mounting
Base mounting
|
| Height | 122mm |
| Width | 55mm |
| Depth | 120mm |
| Net Weight | 0.86kg |
Customer Feedback

More Products
Packaging &Shipping
All products are brand new and intheir original packaging.Provide comprehensive and safe packaging andfast transportation solutions such as DHL, FedEx, small and urgent airfreight, and large sea freight.
FAQ
Q: Are you trading company or manufacturer?
A: Yes, trading company that can give you one-stop station automation purchasing.
Q: Do you have any stock or need buy from other suppliers?
A: We saved lots of products for selling. RTS is our advantage, and we have our own warehouse.
Q: Is there any engineer can help for technical supporting?
A: Sure, we have. Our technical team can help you for selecting PLC, HMI, Servo motor & drive, VFD, low-voltage products, and software. If you need any help, you can contact our technical department directly.
Q: Do you supply 100% original and new products?
A: Of course . No copy, no fake, no refurbished! Original only!!!
Q: Do you sell obsolete products or even very old products?
A: If there is new type to replace, we will suggest you to use new one. If it is not easy for change, we will help to check the old one with good condition. If it is used or other conditions, we will tell you the truth.
Q: How about Customs Duty & Handling Fee?
A: For all customers` orders, we do not charge handing fee, even 1pcs part. When parts arrive at your local custom, if the parts were charged customs duty, we are not responsible for any customs duties or import taxes.
Q: How long is your delivery time?
A: Generally 2-3 working days if the goods in stock. If large quantity, it will take 5-7 working days after getting the payment.
If not common products, it always takes 3-4 weeks or 6-8 weeks to order.
Q: Do you have samples? Is it free or extra ?
A: No. i am sorry, we have no Sample.
Q: What is your terms of payment ?
A:TT, WEST UNION and MoneyGram (100% payment in advance if goods in stock; 30% payment in advance, balance before shipping if long delivery)
description2