Specification
MODEL |
SDR-120-12 |
SDR-120-24 |
SDR-120-48 |
|
OUTPUT |
DC VOLTAGE |
12V |
24V |
48V |
RATED CURRENT |
10A |
5A |
2.5A |
|
CURRENT RANGE |
0~10A |
0~5A |
0~2.5A |
|
RATED POWER |
120W |
120W |
120W |
|
PEAK CURRENT |
15A |
7.5A |
3.75A |
|
PEAKPOWER |
180W |
|||
RIPPLE & NOISE (max.) |
100mVp-p |
100mVp-P |
120mVp-p |
|
VOLTAGE ADJ. RANGE |
12~14V |
24~28V |
48~55V |
|
VOLTAGE TOLERANCE |
+1.0% |
士1.0% |
士1.0% |
|
LINE REGULATION |
士0.5% |
士0.5% |
士0.5% |
|
LOAD REGULATION |
士1.0% |
士1.0% |
士1.0% |
|
SETUP, RISE TIME |
1500ms,60ms/230VAC 3000ms,60ms/115VAC at full load |
|||
HOLD UP TIME (TyP.) |
20ms/230VAC 20ms/115VAC at full load |
|||
INPUT |
VOLTAGE RANGE |
88~264VAC 124~370VDC |
||
FREQUENCY RANGE |
47~63Hz |
|||
POWER FACTOR (Typ.) |
0.93/230VAC 0.96/115VAC at full load |
|||
EFFICIENCY (Typ.) |
89% |
91% |
90.5% |
|
AC CURRENT (TyP.) |
1.4A/115VAC 0.7AV/230VAC |
|||
INRUSH CURRENT (TyP.) |
35A/115VAC 70A/230VAC |
|||
LEAKAGE CURRENT |
<1mA/240VAC |
|||
PROTECTION |
OVERLOAD |
Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage |
||
>150% rated power, constant current limiting with auto-recovery within 3 seconds and shut down op vollage after 3 seconds | ||||
OVER VOLTAGE |
14~17V |
29~33V |
56~65V |
|
Protection type : Shut down o/p voltage, re-power on to recover | ||||
OVER TEMPERATURE |
95℃+5℃℃ (TSW) detect on heatsink of power switch |
|||
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down | ||||
FUNCTION |
DC OK REALY CONTACT RATINGS (max.) |
60Vdc10.3A.30Vdc/1A.30Vac10.5Aresistive load |
||
ENVIRONMENT |
WORKING TEMP. |
-25~+70℃ (Refer to "Derating Curve") |
||
WORKING HUMIDITY |
20~95% RH non-condensing |
|||
STORAGE TEMP., HUMIDITY |
-40~+85'℃,10~95% RH |
|||
TEMP. COEFFICIENT |
+0.03%/℃ (0~50℃) |
|||
VIBRATION |
Component:10~ 500Hz, 2G 10min./1cycle, 60min. each along x, Y, Z axes; Mounting: Compliance to lEC60068-2-6 |
|||
SAFETY &EMC |
SAFETY STANDARDS |
UL508, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004, BSMI CNS14336-1 approved;(meet BS EN/EN60204-1) |
||
WITHSTAND VOLTAGE |
IP-O/P:3KVAC IP-FG:2KVAC OIP-FG:0.5KVAC OIP-DC OK:0.5KVAC |
|||
ISOLATION RESISTANCE |
I/P-OIP, I/P-FG, O/P-FG:>100M Ohms/500VDC/25'℃/70% RH |
|||
EMC EMISSION |
Compliance tO BS EN/EN55032 (CISPR32), BS EN/EN61204-3 CIaSS B, BS EN/EN61000-3-2-3, EAC TP TC 020. CNS13438 Class B |
|||
EMC IMMUNITY |
Compliance to BS EN/EN61000-4-2.3,4.5.6.8.11,BS EN/EN55035,BS EN/EN61000-6-2 (BS EN/EN50082-2)BS EN/EN61204-3, heavy industry leve, EAC TP TC 020, SEMI F47 approved |
|||
OTHERS |
MTBF |
1764.6K hrs min.Telcordia SR-332 (Bellcore) ; 292.1K hrs min.MIL-HDBK-217F(25℃) |
||
DIMENSION |
40*125.2*113.5mm (W*H*D) |
|||
PACKING |
0.67Kg; 20pcs/14.4Kg/1.02CUFT |
|||
Customer Feedback

More Products
Packaging &Shipping
FAQ
description2













![SDR-120-24[1].jpg](https://ecdn6.globalso.com/upload/p/2926/image_product/2025-01/sdr-120-24-1.jpg)
![SDR-120-24[3].jpg](https://ecdn6.globalso.com/upload/p/2926/image_product/2025-01/sdr-120-24-3.jpg)