RST-5000-24 meanwell RST series 5000W Power Supply Switching Power Supply with Single Output MW rst-5000-24
Product Introduction
Description
Features
Specification
MODEL |
RST-5000-24 |
RST-5000-36 |
RST-5000-48 |
|||
OUTPUT |
DC VOLTAGE |
24V |
36V |
48V |
||
RATED CURRENT |
200A |
138A |
105A |
|||
CURRENT RANGE |
0~200A |
0~138A |
0~105A |
|||
RATED POWER |
4800W |
4968W |
5040W |
|||
RIPPLE & NOISE (max.) |
150mVp-p |
200mVp-p |
200mVp-p |
|||
VOLTAGE ADJ. RANGE |
23.5~28.8V |
35~43.2V |
47~57.6V |
|||
Can be adjusted via built-in potentiometer | ||||||
VOLTAGE TOLERANCE |
+1.0% |
士1.0% |
士1.0% |
|||
LINE REGULATION |
士0.5% |
士0.5% |
士0.5% |
|||
LOAD REGULATION |
士0.5% |
士0.5% |
士0.5% |
|||
SETUP, RISE TIME |
2200ms, 80ms at full load |
|||||
HOLD UP TIME (TyP.) |
20ms/230VAC at 75% load 14ms / 230VAC at full load |
|||||
INPUT |
VOLTAGE RANGE |
3y 3-wire/^196~305VAC or3y 4-wire/Y340~530VAC |
||||
FREQUENCY RANGE |
47~63Hz |
|||||
POWER FACTOR (Typ.) |
0.951230VAC(400VAC) at full load |
|||||
EFFICIENCY (Typ.) |
88.5% |
89.5% |
90.5% |
|||
AC CURRENT (TyP.) |
15A230VAC(3y 3-wire/^) 9A1400VAC(3 y 4-wire/Y) |
|||||
INRUSH CURRENT (TyP.) |
75A230VAC(3y 3-wire/^) 50A1400VAC(3 y 4-wire/Y) |
|||||
LEAKAGE CURRENT |
<3.5mA/ ^305VAC(Y 530VAC) |
|||||
PROTECTION |
OVERLOAD |
100~112% rated output power |
||||
User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover | ||||||
OVER VOLTAGE |
30~33.6V |
45~50.4V |
60~67.2V |
|||
Protection type : Shut down o/p voltage, re-power on to recover | ||||||
OVER TEMPERATURE |
Shut down o/p voltage, recovers automatically after temperature goes down |
|||||
FUNCTION |
REMOTE SENSE |
Compensate voltage drop on the load wiring up to 0.3V. Please refer to the Function Manual. |
||||
CURRENT SHARING |
Up to 20000W or (3+1) units. Please refer to the Function Manual. |
|||||
OUTPUTVOLTAGE PROGRAMABLE |
Adjustment of output voltage is allowable to between 20~ 120% of nominal output voltage. Please refer to the Function Manual |
|||||
CONSTANT CURRENT LEVEL PROGRAMMABLE |
Adjustment of constant current level is allowable to between 20 ~ 100% of rated current, Please refer to the Function Manual. |
|||||
AUXILIARY POWER(AUX) |
12V@0.1A(0nly for Remote ON-OFF control) |
|||||
REMOTE ON-OFF CONTROL |
Please refer to the Function Manual. |
|||||
ALARM SIGNAL OUTPUT |
AC fail, DC OK, fan fail, OTP. Please refer to the Function Manual. |
|||||
ENVIRONMENT |
WORKING TEMP. |
-30~+70℃ (Refer to "Derating Curve") |
||||
WORKING HUMIDITY |
20~90% RH non-condensing |
|||||
STORAGE TEMP., HUMIDITY |
-40~+85℃,10~95% RH non-condensing |
|||||
TEMP. COEFFICIENT |
+0.03%/℃ (0~50℃) |
|||||
VIBRATION |
10~500Hz,2G 10min./1cycle, 60min. each along X, Y, Z axes |
|||||
OTHERS |
MTBF |
293.3Khrs min. Telcordia SR-332 (Bellcore);34.7Khrs min. MIL-HDBK-217F(25°C) |
||||
DIMENSION |
460*211*83.5mm (L*W*H) |
|||||
PACKING |
10Kg:1pcs/10.1Kg/0.85CUFT |
|||||
Customer Feedback

More Products
Packaging &Shipping
FAQ
description2