NZM1-XFI30R Eaton circuit breaker series NZM 104603 Y7-104603 Earth-fault release new and 100% original brand
Product Introduction
Specification
Type |
NZM1-XFI30R |
Order Number |
104603 |
Brand |
Eaton |
Place of Origin |
America |
Product Name |
Eaton Moeller series NZM release |
Series |
series NZM |
Special features |
Earth-fault release to IEC/EN 60947-2Not UL/CSA approved Suitable for use in three-phase systems Pulse-current sensitive type A according to core-balance principle For 3 pole NZM1 circuit-breakers and N1 switch-disconnectors Supply voltage-dependent Ue = 200 – 415 V 50/60 HzControl knobs, sealable.Fitted on the right side up to In = 160 A at ICu = 50 kA |
Product Type |
Accessories |
Product Sub Type |
Release |
Application |
In three-phase systems |
Type |
Accessory Earth-fault releases |
Number of poles |
Three-pole |
Frame |
45 mm NZM1 |
Used with |
Three-pole NZM1 N(S)1 |
Sensitivity type |
Pulse-current sensitive as per core-balance principle (type A) |
Voltage rating |
Voltage rating200 - 415 V AC, min. 80 V AC for detection of fault currents type A/AC (dependent on mains voltage) |
Rated operating voltage (Ue) - max |
415 V |
Rated control supply voltage (Us) at AC, 50 Hz - min |
200 V |
Rated control supply voltage (Us) at AC, 50 Hz - max |
415 V |
Rated control supply voltage (Us) at AC, 60 Hz - min |
200 V |
Rated control supply voltage (Us) at AC, 60 Hz - max |
415 V |
Current rating - min |
15 A |
Current rating - max |
160 A |
Rated fault current - min |
0.03 A |
Rated fault current - max |
0.03 A |
Fault current detection range |
50/60 Hz |
Frequency rating |
50 Hz / 60 Hz |
Power on-delay time - min |
30 ms |
Power on-delay time - max |
30 ms |
Mounting Method |
On the right side |
Mounting position |
Vertical and 90° in all directions |
Degree of protection |
IP20 (operating component area) |
Shock resistance |
20 g (half-sinusoidal shock 20 ms) |
Lifespan, mechanical |
20000 operations |
Terminal capacity (solid/flexible conductor) |
As NZM1 standard terminal without ferrules As NZM1 standard terminal with ferrules |
Ambient operating temperature - min |
-5 °C |
Ambient operating temperature - max |
40 °C |
Rated control supply voltage AC 50 Hz |
200 - 415 V |
Rated control supply voltage AC 60 Hz |
200 - 415 V |
Rated fault current |
0.03 - 0.03 A |
Max. power on-delay time |
30 ms |
Max. rated operation voltage Ue |
415 V |
Product Length/Depth |
220mm |
Product Height |
80mm |
Product Width |
105mm |
Product Weight |
1.6kg |
Warranty |
1 year |
Customer Feedback